What is a post and lintel structure?

The post-and-lintel system is a simple method of construction involving the use of vertical and horizontal elements. The verticals support the horizontals, creating one storey of a building. Additional verticals can be placed atop the horizontals to create structures with more than one level.

What supports a lintel?

The most common materials for lintels are timber, steel and concrete. … Precast concrete lintels are economical and provide robust support for structures such as masonry over door and window openings.

Are concrete lintels stronger than steel?

Strength. It is not a myth that steel lintels are stronger than concrete; this is generally the case, but it is a little more complicated. A high strength prestressed concrete lintel can often offer better supporting properties than a similar steel version at certain lengths and can be considerably cheaper.

Why do lintels fail?

The most common reasons for lintel failure are faults with the lintel such as the corrosion of the steel. It’s important to note that lintels may be cracked or blown due to other structural issues such as movement in the wall or foundations.

Are concrete lintels load bearing?

In most cases, the lintels are carrying and transferring huge loads. Even the lightest Fletton bricks weigh about 3 lbs each (or just over a Kg) so 1 square metre of brickwork weighs a massive 25 stones, without the sand and cement joints.

What is the maximum length of a concrete lintel?

Concrete lintels are available in a range of lengths including: 600mm, 900mm, 1200mm, 1350mm, 1500mm and 1800mm.

What is the minimum bearing for a concrete lintel?

150mm

Can I cut a concrete lintel to size?

Cutting. Prestressed concrete Lintels may be cut using a high speed diamond cutting disc. … Under no circumstances should the Ultra-Fire Range of Lintels be cut down in size.

Can you cut concrete floor beams?

While I have never had to cut a Beam & Block floor beam, I have cut many a number of Pre-stressed concrete Lintels without encountering any problems. In fact the cut lengths are actually stronger than what they were originally designed for.

Can I cut concrete fence posts?

You can, with care cut them at angle with a TS400 and good diamond blade. Paint the tops with bitumen paint or similar otherwise the rebar will corode and the concrete spall.

How far should a lintel overhang?

25mm

Is it OK to drill into a lintel?

When drilling into a concrete lintel, you should start with the smallest drill bit for masonry you have in your set. A drill bit of 3mm is a good place to start, and you can then work up from there to get the size of hole you need. When it comes to concrete, the smaller the drill bit, the easier it will penetrate.

How deep is a lintel?

The depth of reinforced brick lintel should be equal to 10 cm or 15 cm or multiple of 10 cm. the bricks are so arranged that 2 to 3 cm wide space is left length wise between adjacent bricks for the insertion of mild steel bars as reinforcement.

How big should a lintel be?

Measure the size of the open space between the walls where the door/window frame is fitted. Add a minimum of 150mm to each end. For example, for a structural opening or clear span of 1,800mm, the minimum lintel length required will be 1,800 + 150 + 150 = 2,100mm.

Are Catnic lintels load bearing?

All lintels are designed to carry a specific safe working load (SWL). If you are not skilled in the method of load assessment, or the load has not been supplied to you by a third party, for advice please contact Catnic Technical Services on 0.

What is the longest Catnic lintel?

Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm – 4800mm (including 4575 but excluding 4500mm).

How do you calculate lintel load?

This is the simplest scenario and basically, means that to calculate the load you take the load of the masonry above the lintel within the load triangle. If any additional loads are applied to the masonry within the load triangle or interaction zone you apply them at 100% and 50% respectively and disperse them at 45°.